Timing of human rhythmic jumping with vertical floor vibrations tends towards mechanically efficient solutions Scientific Reports
The discussion is then extended to the potential effects of large vibrations which, due to the current lack of experimental data, should be experimentally verified in future research. Firstly, we establish the vibrations of 2 m/s2 used in this study as small amplitude within the tested frequency range of 2–2.8 Hz. The adjustment was towards jump timings requiring lower energy input, and with appropriate contact ratio and lower forces.
If the vibrations are large, unlike the timing of 0°, the platform motion does not affect the jumper, as the platform is below its reference position throughout the jumper’s flight phase and hence does not interfere with jumping. A similar trend was also observed on the vibrating platform within the tested FoJ range (Fig. 5j–o), where leg stiffness increased with an increase in FoJ in line with the literature9. Thus, the jump timing behaviour relative to platform motion being dominated by the efficiency of jumping was revealed in this study. Time histories of CoM displacement and GRF, force–displacement relationship, cycle-by-cycle jump timing, cycle-by-cycle mechanical work and cycle-by-cycle leg stiffness for exemplary trials of jumping at four target timings at 2.0 Hz on the vibrating platform are shown in Fig.
Further studies that explored the effect of surface conditions revealed that humans jumping on elastic platforms are spring-like systems in series19,20,21. Timing of human rhythmic jumping with vertical floor vibrations tends towards mechanically efficient solutions
The participants achieved frequencies within ± 0.1 Hz of target FoJ in 79, 79 and 72% of the cycles of jumping with 2.0, 2.4 and 2.8 Hz targets, respectively. The participants were asked to jump at audio-cued frequencies that matched the vibration frequency. The vibration amplitude of 2 m/s2 used in the tests yields peak platform displacements of 1.27, 0.88 and 0.65 cm at the vibration frequencies of 2.0, 2.4 and 2.8 Hz, respectively.
The mean jump heights were 8.23, 6.15 and 4.17 cm at 2.0, 2.4 and 2.8 Hz, respectively (Fig. 3b). Mechanical work was positive and consistent across the cycles except for the inherent cycle-by-cycle variability (Fig. 2g). This variability in time history manifests as an energy spread around the strong harmonics in the Fourier spectrum (Fig. Impact of vertical vibrations on human rhythmic jumping from the Warwick Research Archive Portal 2b,d).
The contact ratio was found as the duration for which the participant exerted more than 10% of their body weight in each cycle17. The impact factor was obtained as the peak GRF normalised with the participant’s body weight for each cycle. The choice of jumping close to the timing of 135° and avoiding 315° is confirmed as statistically significant in this study. This choice likely ensures that the platform does not disrupt the jumper’s flight, the contact ratio is sufficient, injury risks are avoided, positive work is produced, and additional energy input is not required. Results show that relative phase values close to 135° were most achieved (Fig. 6m–o) rather than the four cued timings. This results in a similar landing height, impact factor, contact ratio, work and leg stiffness as jumping on the stationary platform (Fig. 5).
The FoJ, impact factor and contact ratio achieved by the participants in each trial were extracted on a cycle-by-cycle basis from the GRF time history as per Abraham et al.24. At the lowest FoJ of 2.0 Hz tested in this study, some participants took off a quarter cycle before the beat in some trials (Figs. 4 and 6). On the day of the tests, the participants wore a motion capture suit to which the reflective markers were attached. The data from 15 test configurations utilised in this study are part of a larger experimental campaign that involved 39 test configurations per participant. The key findings include participants adjusting their timing to take off from a higher platform position during its downward motion and land at a lower position during the upward motion while maintaining FoJ despite being cued.
The platform moves to its trough position and returns to the reference position as the jumper completes the flight phase. The landing and take-off positions remain the same although the direction of platform motion is the opposite. The faster generation of forces at higher FoJs was likely compensated by an increase in leg stiffness. We provide evidence that leg stiffness is modulated in relation to FoJ.
